WinXP,Win7,Win8
End Select
Next
Next
Set cPPP = Nothing:Set IDE= Nothing
If Disk0 <> "" Then WScript.Echo Left(DskP0,1)&":"&vbTab& Disk0 &vbTab _
&vbCrLf&vbTab&"厂商容量:"&Round(Size0/1000000000) &"GB" _
&vbCrLf&vbTab&"实际容量:"&Round(Size0/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分区状态:"&Right(DskP0,Len(DskP0)-2)
If Disk1 <> "" Then WScript.Echo Left(DskP1,1)&":"&vbTab& Disk1 &vbTab _
&vbCrLf&vbTab&"厂商容量:"&Round(Size1/1000000000) &"GB" _
&vbCrLf&vbTab&"实际容量:"&Round(Size1/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分区状态:"&Right(DskP1,Len(DskP1)-2)
If Disk2 <> "" Then WScript.Echo Left(DskP2,1)&":"&vbTab& Disk2 &vbTab _
&vbCrLf&vbTab&"厂商容量:"&Round(Size2/1000000000) &"GB" _
&vbCrLf&vbTab&"实际容量:"&Round(Size2/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分区状态:"&Right(DskP2,Len(DskP2)-2)
If Disk3 <> "" Then WScript.Echo Left(DskP3,1)&":"&vbTab& Disk3 &vbTab _
&vbCrLf&vbTab&"厂商容量:"&Round(Size3/1000000000) &"GB" _
&vbCrLf&vbTab&"实际容量:"&Round(Size3/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分区状态:"&Right(DskP3,Len(DskP3)-2)
If Disk4 <> "" Then WScript.Echo Left(DskP4,1)&":"&vbTab& Disk4 &vbTab _
&vbCrLf&vbTab&"厂商容量:"&Round(Size4/1000000000) &"GB" _
&vbCrLf&vbTab&"实际容量:"&Round(Size4/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分区状态:"&Right(DskP4,Len(DskP4)-2)
If Disk5 <> "" Then WScript.Echo Left(DskP5,1)&":"&vbTab& Disk5 &vbTab _
&vbCrLf&vbTab&"厂商容量:"&Round(Size5/1000000000) &"GB" _
&vbCrLf&vbTab&"实际容量:"&Round(Size5/1073741824,2) &"GB" _
&vbCrLf&vbTab&"分区状态:"&Right(DskP5,Len(DskP5)-2)
WScript.Echo "↑请输入要监控的硬盘编号,并按回车键"
stdInput = WScript.StdIn.Readline
stdInput=Left(UCase(stdInput),1)
If stdInput > "5" Or stdInput < "0" Then MsgBox "输入错误" :WScript.Quit
If InStr(DskP0, stdInput) Then Call Network(Disk0,Size0,DskP0)
If InStr(DskP1, stdInput) Then Call Network(Disk1,Size1,DskP1)
If InStr(DskP2, stdInput) Then Call Network(Disk2,Size2,DskP2)
If InStr(DskP3, stdInput) Then Call Network(Disk3,Size3,DskP3)
If InStr(DskP4, stdInput) Then Call Network(Disk4,Size4,DskP4)
If InStr(DskP5, stdInput) Then Call Network(Disk5,Size5,DskP5)
Sub Network(Disks,Sizes,DskPs)
sNow=Now
Do
Dim A
'WScript.Echo "已运行"&Ts\3600&"小时"&(Ts mod 3600)\60&"分钟"&(Ts mod 3600) mod 60&"秒"
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'")
For Each B In A
R1 = B.DiskReadBytesPersec
W1 = B.DiskWriteBytesPersec
If RA0 = "" Then RA0 = B.DiskReadBytesPersec Else RA1 = R1 End If
If WA0 = "" Then WA0 = B.DiskWriteBytesPersec Else WA1 = W1 End If
Next
Set A = Nothing
WScript.Sleep(InputS)
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'")
For Each B In A
R2 = B.DiskReadBytesPersec
W2 = B.DiskWriteByte

